00
0
No products in the cart.

Shopping Cart

Sternal Awl

  • Optimal 20 cm working length ensures precise sternal access.
  • Premium German stainless steel offers...
  • Ergonomic handle design provides secure grip, reducing surgeon fatigue.
  • Fully autoclavable, validated for steam sterilization protocols (134°C).
  • Seamlessly integrates with existing surgical instrument trays and setups.
  • ISO 13485 certified manufacturing ensures consistent quality and reliability.

$20.00  $26.00

(250 products available)
Quantity

Precision Sternal Awl: Optimizing Thoracic Closure and Wire Guidance

In complex cardiothoracic procedures, the integrity and efficiency of sternal closure are paramount for patient recovery and preventing complications. Traditional methods can present challenges in achieving consistent pilot holes for sternal wires, potentially leading to increased operative time and suboptimal fixation. The S01-89-00-259 Sternal Awl is engineered to address these critical needs, providing surgeons with a specialized instrument for precise and controlled creation of pilot holes through the sternum. Its design facilitates accurate wire placement, streamlining the sternal wiring process and contributing to enhanced surgical outcomes and patient safety. This instrument is an essential addition to any cardiothoracic surgical suite, ensuring reliable sternal approximation.

Use Cases

  • Creating precise pilot holes through the sternum for sternal wire placement following median sternotomy.
  • Facilitating the atraumatic passage of sternal wires during sternal closure procedures.
  • Ensuring consistent hole alignment to optimize sternal approximation and stability.
  • Assisting in the controlled guidance of wires to minimize tissue trauma and improve procedural efficiency.

Specifications

SKUS01-89-00-259
Overall Length19.0 cm (7.5 in)
SteelAISI 420 Surgical Stainless Steel
FinishSatin
TipTapered, Sharp Point
Quality AssuranceBoil Test: Passed

Care & Sterilization

  • Pre-clean immediately after use to prevent drying of biological debris.
  • Thoroughly clean using an enzymatic detergent and ultrasonic cleaner according to manufacturer guidelines.
  • Sterilize via steam autoclave at 132°C (270°F) for 4 minutes (dynamic-air-removal sterilizer) or 15 minutes (gravity-displacement sterilizer).
  • Inspect for damage or dullness before each use and after cleaning.

General use; follow facility protocols and manufacturer's IFU for specific sterilization and handling procedures.


No reviews yet. Be the first to review this product!